Mitsubishi Electric e-Series chillers & heat pumps

Modular chillers & hydronic heat pumps

Plan your next generation of plant.

Mitsubishi Electric e-Series combines modular capacity with inverter control for commercial water systems. Winter AC helps you assess the options and plan the installation, electrical work, controls and ongoing support.

Mitsubishi Electric e-Series YCL modular chiller. Image: Mitsubishi Electric.
e-Series product image. Image: Mitsubishi Electric.
150–200 kWNominal YCL module range
Up to 6Modules connected per group
R32Refrigerant in the featured range
Two optionsCooling only or reversible heat pump

Why consider modular plant?

Build the system around the building.

For a replacement or a new installation, the e-Series format gives designers flexibility in how capacity is arranged and controlled. The right result starts with the building load, water temperatures and operating pattern.

Respond to changing demand

Inverter compressors and coordinated group control adjust operation as the load changes. Performance should be compared at the conditions your building actually runs at.

Plan capacity in modules

Up to six units can operate as a group. Staged capacity and future additions can be considered where the space, hydraulics, electrical supply and controls allow.

Allow for maintenance

Individual units can be isolated in a suitable system arrangement. Design the remaining capacity and service access around the continuity your building needs.

Six Mitsubishi Electric e-Series modules in an illustrative arrangement. Image: Mitsubishi Electric.
Illustrative six-module arrangement. Image: Mitsubishi Electric. Final layout and clearances depend on the selected equipment and site.

Air-sourced YCL range

Choose cooling only or a heat-pump system.

EACV — cooling only

Chilled water for commercial comfort cooling or suitable process applications. Selection includes the required water temperature, cooling load and ambient conditions.

EAHV — reversible heat pump

Heating or cooling water for suitable hydronic applications. The required seasonal duty and heating-water temperature guide whether this is the right option.

Published YCL brochure model overview
Nominal module Cooling-only model Heat-pump model
150 kW EACV-M1500YCL EAHV-M1500YCL
180 kW EACV-M1800YCL EAHV-M1800YCL
200 kW EACV-M2000YCL EAHV-M2000YCL

Base model names are shown. The brochure also lists built-in-header (-N) and anti-corrosion (-BS) versions. Confirm current New Zealand availability, options and lead times for the project.

Nominal ratings are a starting point for selection. Published cooling capacities use 35°C outdoor dry-bulb temperature and 12°C/7°C inlet/outlet water; heating capacities use 7°C outdoor dry-bulb temperature and 40°C/45°C water. Actual duty depends on operating conditions. Source: Mitsubishi Electric YCL brochure MEES25K096, July 2026.

Manufacturer information

Review the operating ranges, model data and options, then discuss your site requirements with Winter.

Plant space & pipework

Look beyond the chiller footprint.

The built-in-header option brings common water connections within the module arrangement. Pumps and the wider hydraulic system still need to be selected and coordinated for the job.

We review flow requirements, water condition, isolation, electrical capacity, noise, service access and controls with the project team. Structural and seismic requirements are coordinated with the relevant designers.

Read about our chiller replacement approach
Mitsubishi Electric e-Series built-in-header product illustration. Image: Mitsubishi Electric.
Built-in-header product illustration. Image: Mitsubishi Electric. The featured units do not include a pump.

e-Series in application

A practical option for rooftop plant.

Roof access, lifting routes, airflow and maintenance clearances all shape a replacement. We assess the installation requirements before agreeing the plant selection and shutdown programme.

Example e-Series installation. Image: Mitsubishi Electric.
Example e-Series installation. Image: Mitsubishi Electric.

Working with Winter AC

One coordinated installation scope.

  1. Assess the site

    Review existing plant, drawings, operating issues and the building’s heating or cooling requirements.

  2. Select the system

    Work with your consultant and equipment supplier on duty, temperatures, options and the complete installed scope.

  3. Plan the changeover

    Coordinate mechanical and electrical work, controls, lifting, access and agreed shutdown windows.

  4. Commission & support

    Agree the testing, handover records and ongoing maintenance needed for the completed installation.

In-house mechanical
& electrical capability
SiteWise Gold 2026/27, powered by Site Safe
SiteWise Gold 2026/27
$20m public liability

e-Series questions, answered

How is an e-Series chiller different from VRF?

An e-Series chiller heats or cools water for a hydronic system, depending on the model. VRF systems distribute refrigerant to compatible indoor units. The right approach depends on the building, its existing services and the required heating or cooling duty.

Can an e-Series heat pump replace a boiler?

It may suit some heating systems, but the required water temperature, winter duty and existing heat emitters need to be checked. The supplied YCL brochure lists hot-water outlet temperatures up to 55°C for the EAHV models, subject to the operating envelope. Higher-temperature systems may need changes or a different heat-pump solution. EACV cooling-only models do not provide heating.

Can individual modules be maintained while others operate?

A modular arrangement can retain partial capacity while an individual unit is isolated for maintenance. This depends on the hydraulic layout, isolation, controls and available remaining capacity. Required standby capacity should be designed around the building’s operating needs.

Will the new plant connect to our building management system?

We review the existing BMS with your controls provider and confirm the interface, points, sequencing, alarms and commissioning scope. Compatibility and any additional controllers or gateways are checked during selection.

What does an installed e-Series system cost?

Pricing is project-specific. The proposal needs to cover the selected modules, pumps and pipework, electrical supply, controls, lifting and access, engineering, commissioning and ongoing support. Send the site address, existing plant details and any drawings so we can establish the scope.

Replacement, upgrade or new project

Let’s look at your building.

Send the site address, existing chiller details, drawings and required timeframe. Include any limits on shutdowns or access so we can plan around them.

Based in Ngauranga. Serving Greater Wellington.

Wellington City, Lower Hutt, Upper Hutt, Porirua and Kāpiti. For Wairarapa and projects further afield, contact us to discuss delivery and ongoing service arrangements.